China Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator, Find details about China Baby Incubator, Baby Infant from Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
HB103 | HB102 | HB101 | HB100 | |
Mattress to Hood | 450mm | 450mm | 450mm | 410mm |
Observation side of hood | Two incline | Two incline | Two incline | Two incline |
Operate port | 6 | 6 | 6 | 4 |
Front access panel | 826*310mm | 826*310mm | 826*310mm | 826*280mm |
Mattress tray size | 630*360mm | 630*360mm | 630*360mm | 630*360mm |
Power supply | ≤400VA | ≤400VA | ≤400VA | ≤400VA |
Temperature controlled by microcomputer | Air and skin temp Air temp | Air and skin temp Air temp | Air temp | Air temp |
Air temp control range | 20ºC-37ºC | 20ºC-37ºC | 20ºC-37ºC | 20ºC-37ºC |
37ºC-39ºC | 37ºC-39ºC | 37ºC-39ºC | -------- | |
Skin Temp control range | 30ºC-37ºC | 30ºC-37ºC | ----------- | ------------ |
37ºC-38ºC | 37ºC-38ºC | ------------ | ------- | |
Skin Temp sensor accuracy | ≤0.3ºC | ≤0.3ºC | ------------ | ------- |
Humidity display range | 5%-99% | ------------- | --------- | -------------- |
Temperature fluctuation | ≤0.5ºC | ≤0.5ºC | ≤0.5ºC | ≤0.5ºC |
Mattress temperature uniformity | ≤0.8ºC | ≤0.8ºC | ≤0.8ºC | ≤0.8ºC |
Temperature rise time | ≤30min | ≤30min | ≤30min | ≤30min |
Noise level within hood environment | ≤55dB | ≤55dB | ≤55dB | ≤55dB |
Alarms | ||||
Power failure alarm | yes | Yes | yes | yes |
Fan failure alarm | yes | Yes | yes | yes |
Sensor failure alarm | yes | Yes | yes | yes |
High air temp alarm | +1.5ºC | +1.5ºC | +1.5ºC | +1.5ºC |
Low air tem alarm | -2.5ºC | -2.5ºC | -2.5ºC | -2.5ºC |
High skin temp alarm | +1.0ºC | +1.0ºC | ---- | --- |
Low skin tem alarm | -1.0ºC | -1.0ºC | ----- | |
Over air tem alarm | ≤38ºC, ≤40ºC | ≤38ºC, ≤40ºC | ≤38ºC, ≤40ºC | ≤38ºC |
Over skin tem alarm | ≤38ºC, ≤39ºC | ≤38ºC, ≤39ºC | ≤38ºC, ≤39ºC | -- |
System failure alarm | yes | yes | yes | -- |
Alarm silence function | yes | yes | yes | --- |
Operational condition | ||||
Environment temperature | +20ºC-+30ºC | +20ºC-+30ºC | +20ºC-+30ºC | +20ºC-+30ºC |
Environment relative humidity | 5%-99% | 5%-99% | 5%-99% | 5%-99% |
Environment air velocity of flow | <0.3m/s | <0.3m/s | <0.3m/s | <0.3m/s |
Others | ||||
RS232 interface | yes | yes | yes | yes |
Railing | yes | yes | yes | ---- |
Infant bed tilt adjustment | ±10° step less | ±10° step less | ±10° step less | --------- |
Max load of mattress tray | 10kg | 10kg | 10kg | 10kg |
IV Pole Max load | 2kg | 2kg | 2kg | 2kg |