2kVA Solar Inverter with MPPT Solar Charge Controller

China 2kVA Solar Inverter with MPPT Solar Charge Controller, Find details about China Solar Inverter, MPPT Solar Charge Controller from 2kVA Solar Inverter with MPPT Solar Charge Controller

Model NO.
HF4830U60-H
Wave
Pure Sine Wave
Rated Current
40A
Communication Interface
USB/ RS485(Bluetooth/WiFi/GPRS)/ Dry Node Control
Max Charging Current
40A
Max PV Open Voltage
100V
Max Power
3000W
PV Charging Current
0-60A
Trademark
HonorInsight or OEM
Transport Package
Carton Box with Foam Paper
Origin
China
HS Code
85044084
Model NO.
HF4830U60-H
Wave
Pure Sine Wave
Rated Current
40A
Communication Interface
USB/ RS485(Bluetooth/WiFi/GPRS)/ Dry Node Control
Max Charging Current
40A
Max PV Open Voltage
100V
Max Power
3000W
PV Charging Current
0-60A
Trademark
HonorInsight or OEM
Transport Package
Carton Box with Foam Paper
Origin
China
HS Code
85044084
2kVA Solar Inverter with MPPT Solar Charge Controller 
 

Product Description

 

HF series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage &mains charging energy storage and AC sine wave output. Thanks to DSP control and advanced controlalgorithm, it has high response speed, high reliability, and high industrial standard.

2kVA Solar Inverter with MPPT Solar Charge Controller




 

Overview

 

Basic system introduction 

The figure below shows the system application scenario of this product. A complete system consists of the following parts: 
1. PV module: Convert light energy into DC power, and charge the battery through the all-in-one solar charge inverter, or directly invert into AC power to drive the load. 
2. Mains or generator: Connected at the AC input, to power the load while charging the battery. If the mains or generator is not connected, the system can also operate normally, and the load is powered by the battery and PV module. 
3. Battery: Provided to ensure normal power supply to the system loads when solar energy is insufficient and the Mains is not connected. 
4. Household load: Allow connection of various household and office loads, including refrigerators, lamps, TVs, fans and air conditioners. 
5. All-in-one solar charge inverter: The energy conversion unit of the whole system. Specific system wiring method depends on the actual application scenario. 



2kVA Solar Inverter with MPPT Solar Charge Controller



 

Detailed Photos

2kVA Solar Inverter with MPPT Solar Charge Controller2kVA Solar Inverter with MPPT Solar Charge Controller2kVA Solar Inverter with MPPT Solar Charge Controller


 

Product Parameters

ModelsHF2420U60-100HF2430U60-100
AC mode 
Rated input voltage110/120Vac
Input voltage range(90Vac~140Vac) ±2%
Frequency50Hz/ 60Hz (Auto-detection)
Frequency Range47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protectionCircuit breaker
Efficiency>95%
Conversion time (bypass and inverter)10ms (typical)
AC reverse protectionAvailable
Maximum bypass overload current40A
Inverter mode 
Output voltage waveformPure sine wave
Rated output power (VA)20003000
Rated output power (W)20003000
Power factor1
Rated output voltage (Vac)120Vac
Output voltage error±5%
Output frequency range (Hz)50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency>90%

Overload protection
(102% < load <110%) ±10%: report error and turn off the output after 5 minutes;(110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds;(Load >150% ±10%): report error and turn off the output after 5 seconds;
Peak power(W)30004500
Loaded motor capability1HP2HP
Output short circuit protectionCircuit breaker
Bypass breaker specifications40A
Rated battery input voltage48V (Minimum starting voltage 44V)
Battery voltage rangeUndervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on the LCD screen)
Power saving mode
AC charging
Load ≤25W
Battery typeLead-acid or lithium battery
Maximum charge current30A
Charge current error± 5Adc
Charge voltage range40 -60Vdc
Short circuit protectionCircuit breaker and blown fuse
Circuit breaker specifications40A
Overcharge protectionAlarm and turn off charging after 1 minute
PV charging 
Maximum PV open circuit voltage100Vdc
PV operating voltage range30-100Vdc
MPPT voltage range30-85Vdc
Battery voltage range20-33Vdc
Maximum output power1400W
PV charging current range (can be set)0-60A
Charging short circuit protectionBlown fuse
Wiring protection
Certified specifications
Reverse polarity protection
CertificationCE(IEC/EN62109-1
EMC certification levelEN61000, C2
Operating temperature range-15°C to 55°C
Storage temperature range-25°C ~ 60°C
Humidity range5% to 95% (Conformal coating protection)
Noise≤60dB
Heat dissipationForced air cooling, variable speed of fan
Communication interfaceUSB/RS485(Bluetooth/WiFi/GPRS)/Dry node control
Size (L*W*D)378mm*280mm*103mm
Weight (kg)6.8






Wiring Specifications and Circuit Breaker Selection 

Wiring and installation must comply with national and local electrical codes. 
Recommended PV array wiring specifications and circuit breaker selection: Since the output current of the PV array is affected by the type, connection method and illumination angle of the PV module, the minimum wire diameter of the PV array is calculated according to its short-circuit current; refer to the short-circuit current value in the PV module specification (the short-circuit current is constant when the PV modules are connected in series; the short-circuit current is the sum of the short-circuit currents of all PV modules connected in parallel); the short-circuit current of the PV array shall not exceed the maximum input current. 


Refer to the table below for PV input wire diameter and switch:
ModelsRecommended PV wiring diameterMaximum PV input currentRecommended air switch or circuit breaker type
HF2420U60-100 8mm2/8AWG
 
40A
 
2P-63A
 
HF2430U60-1008mm2/8AWG
 
40A
 
2P-63A
 




Refer to the table below for recommended AC input wire diameter and switch:
ModelsRecommended AC input wiring diameterMaximum bypass input currentRecommended air switch or circuit breaker type
HF2420U60-100 8mm2/8AWG40A2P-63A
HF2430U60-1008mm2/8AWG40A2P-63A
**Note: There is already an appropriate circuit breaker at the Mains input wiring terminal, so it is not necessary to add one more.

 

Recommended battery input wire diameter and switch selection:
ModelsRecommended battery wiring diameterRated battery dischargeMaximum charge currentRecommended air switch or circuit breaker type
HF2420U60-100 25mm2/3AWG100A100A2P-120A
HF2430U60-10030mm2/2AWG140A100A2P-160A





Recommended AC output wiring specifications and circuit breaker selection:
ModelsRecommended AC output wiring diameterRated inverter AC outputMaximum bypass output currentRecommended air switch or circuit breaker type
HF2420U60-100 8mm2/8AWG16.7A40A2P-63A
HF2430U60-1008mm2/8AWG25A40A2P-63A



**Note: The wiring diameter is for reference only. If the distance between the PV array and the all-in-one solar charge inverter or the distance between the all-in-one solar charge inverter and the battery is relatively long, using a thicker wire can reduce the voltage drop to improve system performance.

**Note: The above are only recommended wiring diameter and circuit breaker. Please select the appropriate wiring diameter and circuit breaker according to actual situations.

 

Application

2kVA Solar Inverter with MPPT Solar Charge Controller
2kVA Solar Inverter with MPPT Solar Charge Controller

 

2kVA Solar Inverter with MPPT Solar Charge Controller
2kVA Solar Inverter with MPPT Solar Charge Controller