attery input data | UPT-H-3.6K | UPT-H-5K | UPT-H-8K-EU |
Battery Type | Lead-acid or Li-Ion | Lead-acid or Li-Ion | Lead-acid or Li-Ion |
Battery Voltage Range (V) | 40~60V | 40~60V | 40~60V |
Max.Charging Current (A) | 90A | 125A | 190A |
Max.Discharging Current (A) | 90A | 125A | 190A |
Charging Curve | 3 Stages/Equalization | 3 Stages/Equalization | 3 Stages/Equalization |
External Temperature Sensor | Optional | Optional | Optional |
Charging Strategy for Li-on Battery | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS |
PV String Input Data | |||
Max. Input Power | 4680W | 6500W | 9880W |
PV Input Voltage | 370V (100V~500V) | 370V (100V~500V) | 370V (100V~500V) |
MPPT Range (V) | 125V-425V | 125V-425V | 125V-425V |
Start-up voltage (V) | 125V | 125V | 125V |
PV Input Current (A) | 11A+11A | 11A+11A | 18A+18A |
No.of MPPT Trackers | 2 | 2 | 2 |
No.of Strings Per MPPT Trackers | 1/1 | 1/1 | 2+2 |
AC Output Data | |||
Rated AC Output and UPS Power(W) | 3600W | 5000W | 7600W |
Power (off grid) | 2 times of rated power,10S | 2 times of rated power,10S | 2 times of rated power,10S |
AC Output Rated Current (A) | 15.7A | 21.7A | 31.7A/33A |
Output Frequency and Voltage | 50/60Hz;220Vac/230Vac/240Vac (Single phase) | 50/60Hz;180Vac-240Vac | |
PV Arc Fault Detection | Integrated | ||
PV Input Lightning | Integrated | ||
Anti-islanding | Integrated | ||
PV String Input Reverse Polarity | Integrated | ||
Insulation Resistor Detection | Integrated | ||
Residual Current Monitoring Unit | Integrated | ||
Output Over Current | Integrated | ||
Output Shorted | Integrated | ||
Output Over Voltage | Integrated | ||
Certifications and Standards | |||
Grid Regulation | VDE-ARN4105,VDE0126,AS4777,NRS2017,G98,G99,EN50438 | ||
Safety Regulation | IEC62109-1,IEC62109-2 | ||
EMC | EN61000-6-1,EN61000-6-3 | ||
attery input data | UPT-H-3.6K | UPT-H-5K | UPT-H-8K-EU |
Battery Type | Lead-acid or Li-Ion | Lead-acid or Li-Ion | Lead-acid or Li-Ion |
Battery Voltage Range (V) | 40~60V | 40~60V | 40~60V |
Max.Charging Current (A) | 90A | 125A | 190A |
Max.Discharging Current (A) | 90A | 125A | 190A |
Charging Curve | 3 Stages/Equalization | 3 Stages/Equalization | 3 Stages/Equalization |
External Temperature Sensor | Optional | Optional | Optional |
Charging Strategy for Li-on Battery | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS |
PV String Input Data | |||
Max. Input Power | 4680W | 6500W | 9880W |
PV Input Voltage | 370V (100V~500V) | 370V (100V~500V) | 370V (100V~500V) |
MPPT Range (V) | 125V-425V | 125V-425V | 125V-425V |
Start-up voltage (V) | 125V | 125V | 125V |
PV Input Current (A) | 11A+11A | 11A+11A | 18A+18A |
No.of MPPT Trackers | 2 | 2 | 2 |
No.of Strings Per MPPT Trackers | 1/1 | 1/1 | 2+2 |
AC Output Data | |||
Rated AC Output and UPS Power(W) | 3600W | 5000W | 7600W |
Power (off grid) | 2 times of rated power,10S | 2 times of rated power,10S | 2 times of rated power,10S |
AC Output Rated Current (A) | 15.7A | 21.7A | 31.7A/33A |
Output Frequency and Voltage | 50/60Hz;220Vac/230Vac/240Vac (Single phase) | 50/60Hz;180Vac-240Vac | |
PV Arc Fault Detection | Integrated | ||
PV Input Lightning | Integrated | ||
Anti-islanding | Integrated | ||
PV String Input Reverse Polarity | Integrated | ||
Insulation Resistor Detection | Integrated | ||
Residual Current Monitoring Unit | Integrated | ||
Output Over Current | Integrated | ||
Output Shorted | Integrated | ||
Output Over Voltage | Integrated | ||
Certifications and Standards | |||
Grid Regulation | VDE-ARN4105,VDE0126,AS4777,NRS2017,G98,G99,EN50438 | ||
Safety Regulation | IEC62109-1,IEC62109-2 | ||
EMC | EN61000-6-1,EN61000-6-3 |