HC-C001 Cheap Multi-parameter Patient Monitor/medical portable patient monitor/patient monitor
Features for HC-C001 Cheap Multi-parameter Patient Monitor/medical portable patient monitor/patient monitor :
Technical Specifications for 7 inch patient monitor:
NIBP Monitoring | |
Measuring method | Oscillometric Technique |
Pneumatic pressure measuring range | 0 mmHg~300mmHg |
Accuracy | ±3 mmHg |
Cuff inflation time | <10 seconds (typical adult cuff) |
Measurement time on average | < 90 seconds |
Initial cuff inflation pressure | Adult and infant mode: 180mmHg Neonate mode: 120mmHg |
Overpressure protection limit | Adult and infant mode: 300 mmHg Neonate mode: 140 mmHg |
Measuring range | Systolic pressure: |
| Adultt: 40mmH~255mmHg |
| Infant: 40mmHg~200mmHg |
| Mean arterial pressure: |
| Adult:20mmHg~215mmHg |
| Infant: 20mmHg~165mmHg |
| Diastolic pressure: |
| Adult:10mmHg~195mmHg |
| Infant: 10mmHg~150 mmHg |
NIBP accuracy | Maximal mean difference: ±5 mmHg Maximal standard deviation: 8 mmHg |
Measurement mode | Manual, Auto, STAT |
TEMP Monitoring | |
Measuring range | 32.0ºC~43.0ºC |
Responding time | ≤20s |
SpO2 & Pulse Rate Monitoring | |
Transducer | dual-wave length LED |
SpO2 measuring range | 35%~100% |
SpO2 display accuracy | Not greater than 3% for SpO2 range from 70% to 100% |
PR measuring range | 30bpm~240bpm |
PR measuring accuracy | ±2bpm or ±2%, whichever is greater |
ECG Monitoring | |
Input signals range in amplitude | ±(0.4mVp~5mVp) |
Heart rate display range | 15bpm~350bpm |
HR Display accuracy | ±1% or ±2bpm, whichever is greater |
Sweeping speed | 6.25mm/s,12.5mm/s, 25mm/s, 50mm/s tolerance: ≤10% |
Time constant | Monitoring mode≥0.3s Diagnostic mode≥3.2s |
Frequency response | Monitoring mode: 0.5Hz~40Hz Diagnostic modes: 0.05Hz~75Hz |
RESP Monitoring | |
Monitoring range | 0rpm~150rpm |
Monitoring accuracy | ±5% or ±2 rpm, whichever is greater |
Other Technical Specifications | |
Power supply | 100~240VAC, 50/60Hz |
Rechargeable Li-ion battery specification | 14.8V 2200mAh |
Display mode | 7 inches TFT color LCD |
Resolution | 800*480pixel |
Alarming mode | Audible & visual alarm |
Communication | Serial/Net port |
Standard Configuration | |
ECG, RESP, SpO2, NIBP, TEMP, PR |
Adult / Infant measurement modes;
Visual and audible alarms;
Built-in rechargeable battery;
7'' high resolution color TFT display, 4-channel waveform display;
Standard parameters: ECG, RESP, SpO2, NIBP, TEMP, PR;
Up to 800 groups of NIBP data & 120-hour ECG waveform storage and recall;
Up to 400 groups of SpO2 data storage and recall;
480-hour graphic and tabular trends for all parameters;
Protection against interference from defibrillator, electrosurgical knife;