3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker

China 3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker, Find details about China Price List MCCB Schneider, MCB and MCCB from 3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker

Model NO.
MCCB
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, UL, CCC
Rated Insulation Voltage Ui(V)
1600
Rated Impulse Withstand Voltage Uimp(Kv)
12
OEM
Yes
ODM
Yes
Product Name
DC MCCB
Rated Insulation Voltage
1500V
Material
High Standard Plastic Copper and Silver
Certificate
Ce/ISO9001
Trademark
KAYAL
Transport Package
Standard Carton
Origin
China
HS Code
1904031930
Model NO.
MCCB
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, UL, CCC
Rated Insulation Voltage Ui(V)
1600
Rated Impulse Withstand Voltage Uimp(Kv)
12
OEM
Yes
ODM
Yes
Product Name
DC MCCB
Rated Insulation Voltage
1500V
Material
High Standard Plastic Copper and Silver
Certificate
Ce/ISO9001
Trademark
KAYAL
Transport Package
Standard Carton
Origin
China
HS Code
1904031930

3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker

DC system-specific circuit breakers are used in rated insulation voltage of 1600V and a rated operating voltage of DC1500V and below, and rated operating currents of 250A and below. C ircuit breakers are mainly used for overload and short circuit protection of distributed power and protection circuits and power equipment in DC systems . U nder normal circumstances can be used as a line of infrequent conversion and DC motor infrequent start.

1.Normal conditions of use

Ambient air temperature does not exceed the upper limit of +70ºC, the lower limit of not less than -40ºC , 24-hour average does not exceed +35ºC. (Note: Circuit breakers for use in ambient air temperatures above + 70ºC or below -40ºC should be consulted with the manufacturer);
The installation site of the altitude does not exceed 2000m (2000m above the need for the corresponding derating)
The relative temperature of the atmosphere is not more than 50% at the highest temperature around +40ºC, and can be compared at a lower temperature.High relative humidity (for example, 90% at 20ºC), and the consideration of temperature change on the surface of the product dew.
2.Normal installation conditions
Installation conditions: the general should be vertical installation or horizontal installation;
Installation categories: Class III of circuit breaker main circuit, control circuit and auxiliary circuit are class II.
Pollution level: Three
3.Normal storage and transport conditions
The temperature limit is not lower than -40ºC,the upper limit does not exceed +70ºC Relative humidity (25ºC) does not exceed 95ºC;
The product should be lightly moved during transport,should not be reversed should be acoided violent collision Main technical parameters

Main technical parameters 

Frame level250ARated working voltageDC500V/DC1000V DC1250V/DC1500V
Rated working current(A)100/125/140/160
/180/200/225/250
Rated insulation voltageDC160
Pole number2Arcing distance≤50mm
Breaking capacityIcu=Ics=15kAMechanical life200
Short circuit 
instantaneous setting
5~10Degree of protectionIp20
Standard ruleGB14048.2 IEC60947

Description of protection

Overload long delay protection

Ambient temperatureTest currentAppointment timeStarting state
+50ºC±2ºC1.05In≥No actionCold state
1.3In<2h actionHot state

Short-circuit transient protection

Ambient temperatureTest currentAppointment timeStarting state

+10ºC~+40ºC

4In or 8In≥200msNo action
6In or 12In<200msaction

Derated coefficient when ambient temperature changes

Ambient temperature40ºC45ºC50ºC55ºC60ºC65ºC
Derated coefficient1In0.97In0.93In0.89In0.85In0.82In

A comparative relationship between the rated current of a circuit breaker and the cross section of a linked wire

Rated current100A125A140A160A180A200A225A250A
Cable intercepting area35mm²50mm²70mm²95mm²120mm²

.High altitude derated coefficient

Altitude2000m3000m4000m5000m
Operating voltage derating coefficient10.90.80.7
Operating current derating coefficient10.960.930.9

3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker

3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker
3 Phase 100A MCCB 630 AMP Moulded Case Circuit Breaker