China Pharmaceutical Industry Humidifier Air Handling Unit Fan Coil Unit Types Ahu, Find details about China Ahu, Air Handling Unit from Pharmaceutical Industry Humidifier Air Handling Unit Fan Coil Unit Types Ahu
unit characteristics | Model: GT-ZKW-()DX | 20 | 30 | 40 | 50 | 65 | 80 | 100 | |
Cooling capacity | KW | 10.1 | 15.3 | 20.3 | 25.5 | 32.3 | 38.6 | 52.0 | |
Heating capacity | KW | 10.3 | 15.7 | 20.8 | 26.1 | 33.5 | 39.5 | 53.2 | |
Supply air volume | M³/h | 2000 | 3000 | 4000 | 5000 | 6500 | 8000 | 10000 | |
Margin blast pressure | Pa | 200 | 250 | 300 | 300 | 400 | 400 | 500 | |
Power | 3N-380V-50Hz | ||||||||
Indoor unit | Blower | Type | High efficient centrifugal fan | ||||||
KW | 0.55 | 0.75 | 1.5 | 2.2 | 3.0 | 3.0 | 5.5 | ||
Chilled water coil (option) | Type | High efficient copper tube aluminum fin | |||||||
Water flow (m³/h) | 1.7 | 2.6 | 3.5 | 4.4 | 5.6 | 6.6 | 8.9 | ||
Segment length (mm) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | ||
Heater | Type | Stainless steel tubular electric heater/ Steam heat coil/ Hot water heat coil | |||||||
KW | 6 | 9 | 12 | 18 | 24 | 24 | 30 | ||
segment length (mm) | 300 | 300 | 300 | 300 | 400 | 400 | 400 | ||
Humidifier | Type | Electrode type/ Steam/ Electrothermic type/ Wet film | |||||||
KW | 3 | 4 | 5 | 8 | 8 | 12 | 12 | ||
segment length (mm) | 400 | 400 | 400 | 400 | 400 | 400 | 400 | ||
Air filter | Type | Primary filter G4( Middle filter F8 &Nanocrystalline carbon filter) | |||||||
Noise | dB(A) | 60 | 60 | 61 | 62 | 63 | 63 | 65 | |
Size | L (mm) | 1800 | 2000 | 2000 | 2100 | 2100 | 2200 | 2400 | |
W (mm) | 730 | 1030 | 1030 | 1030 | 1140 | 1340 | 1340 | ||
H (mm) | 788 | 788 | 1115 | 1115 | 1115 | 1115 | 1420 | ||
Weight | KG | 140 | 180 | 320 | 400 | 580 | 660 | 800 | |
Outdoor unit | Model: GT-WL- | 10 | 15 | 20 | 25 | 35 | 40 | 55 | |
Compressor A | Type | Hermetic Scroll ( Fixed frequency system) | |||||||
Quantity | 1 | 1 | 1 | 1 | 1 | 2 | 2 | ||
Input power A | KW | 3.4 | 4.8 | 6.3 | 8.0 | 9.8 | 12.7 | 16.1 | |
Compressor B | Type | Hermetic Scroll( Frequency conversion system) | |||||||
Quantity | 1 | 1 | 1 | 1 | 1 | 2 | 2 | ||
Input power B | KW | 3.3 | 4.6 | 6.2 | 7.7 | 9.7 | 12.6 | 15.6 | |
Refrigerant | Type | R22/R407C/R410A | |||||||
Mode | Thermal expansion valve/ Electronic expansion valve | ||||||||
Noise | dB(A) | 63 | 63 | 64 | 64 | 65 | 65 | 76 | |
Size | L (mm) | 850 | 850 | 980 | 980 | 980 | 1880 | 1880 | |
W (mm) | 850 | 850 | 980 | 980 | 980 | 980 | 980 | ||
H (mm) | 1080 | 1080 | 1080 | 1080 | 1234 | 1080 | 1080 | ||
Weight | KG | 130 | 135 | 150 | 180 | 220 | 280 | 320 | |
Connection Pipe diameter | liquid pipe(mm) | 12.7 (9.52) | 12.7 (9.52) | 12.7 (12.7) | 15.88 (12.7) | 15.88 (12.7) | 15.88*2 (12.7*2) | 15.88*2 (12.7*2) | |
gas pipe(mm) | 15.88 (12.7) | 19.05 (15.88) | 19.05 (15.88) | 28.6 (22.23) | 15.88 (12.7) | 22.23*2 (19.05*2) | 28.6*2 (22.23*2) |
Application
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.
Air handling unit structure diagram
1. Conventional
2. Technical purification
3. Heat recovery type