Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

China Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle, Find details about China Glycol Chiller, Chiller from Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

Model NO.
ESSA Series
Application Fields
Pharmaceutical
Application Machine
Reaction Kettle
Certification
CE
Condition
New
Compressor
Copeland
Refrigerant
R404A
Cabinet
PU Coated for Anti-Corrosion
Condenser
Aluminum Finned Copper Tube
Evaporator
Plate, Shell Tube, Coil in Tank
Controller
Microcomputer Control Punp
Expansion Valve
Danfoss, Emerson
Color
Blue White
Tank
Stainless Steel, Unpressurized
Water Pump
Centrifugal Cnp
Solenoid Valve
Optional Castel, Hongsen
Fan
Axial
Service
OEM, ODM
Trademark
ESACIR
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: 0, -5, -10C
Origin
Shenzhen
HS Code
8418692090
Model NO.
ESSA Series
Application Fields
Pharmaceutical
Application Machine
Reaction Kettle
Certification
CE
Condition
New
Compressor
Copeland
Refrigerant
R404A
Cabinet
PU Coated for Anti-Corrosion
Condenser
Aluminum Finned Copper Tube
Evaporator
Plate, Shell Tube, Coil in Tank
Controller
Microcomputer Control Punp
Expansion Valve
Danfoss, Emerson
Color
Blue White
Tank
Stainless Steel, Unpressurized
Water Pump
Centrifugal Cnp
Solenoid Valve
Optional Castel, Hongsen
Fan
Axial
Service
OEM, ODM
Trademark
ESACIR
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: 0, -5, -10C
Origin
Shenzhen
HS Code
8418692090
Low Temperature Glycol Chiller Air Cooled Chiller For Reaction Kettle

1. Air cooled industrial glycol chiller applications

Eurostars industrial chillers are depended upon to serve the process cooling needs of a wide variety of industries, and are selected due to their advanced designs which are focused on energy efficiency, reduction of water consumption, reduced maintenance, and improved reliability of both the cooling system and the processes and equipment it serves. It is widely used for the following industry:
(1)Plastics:
injection moulding, PET, blow moulding, woven sack extrusion, sheet and profile extrusion, thermoforming, presses, etc 
(2)Automobile and Mechanical Engineering
machine tool, induction hardening and heating, welding machines, rolling mills, presses, cutting, profiling, polishing, electric discharge machine, hydraulic oil cooling, heat treatment, component washing, component cooling, environmental test chambers, drive cooling, plasma spray, vacuum systems, etc
(3)Food and Beverages:
Microbreweries, confectionary, bakeries, distilleries, wineries, bottling, carbonation, vegetable, meat and fish processing,
(4)Medical
MRI, PET scan, CT scan, linear accelerator, electron microscope, etc
(5)Metal working
Water jet cutting, power press, hydraulic oil cooling, laser cutting, aluminium extrusion, precious metal processing, etc
(6)Lasers
cutting, welding, marking, profiling, optics, medical, engraving, etc
(7)Paper and related
printing machine, labeling machine, cardboard making, plastic film machine, etc
(8)Others
 textile, semiconductor, air compressor, concrete batching, dynamometer, furnace, etc

2. Eurostars air cooled glycol chiller main components
(1)Hermetic scroll compressors-Copeland
(2)Stainless steel centrifugal pump
(3)Non ferrous water piping
(4)Stainless steel chilled water insulated tank
(5)Stainless steel evaporator (housed in tank); Plate and shell tube type is optional
(6)Electronic temperature controller with full feature controls
(7)Attractive and durable steel cabinet (SS casing is optional)
(8)Designed for ease of accessibility to components
(9)Low ambient start-up package
(10)Split system (remote condenser) also available

Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

3. Eurostars chiller diagram
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

4. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
Including for compressor motors, water pump motors and fan motors.
There are some situations that will cause damage to motors in an industrial chiller, such as instable voltage, ambient temperature too high which mostly caused by poor ventilation, returning water temperature too high, etc. In these cases the motor running current will get higher than its safe range, which might damage the motor if keep it working. Built in protection for overload will shut down the chiller and warn you if the motors are working unhealthily.
(2)Compressor motor overheat protection
Compressor is the heart of an industrial chiller, it reflects problem of the whole chiller unit. The situation causes compressor motor overheat includes poor ventilation, dusty condenser, refrigerant circuit blocking, lack of refrigerant, etc.
This alarm reminds you to check through the chiller unit, prevent it from burning out because of unhealthy working condition. 
(3)Discharge temperature overhigh protection
Discharge temperature overhigh normally caused by high suction temperature, high compressor motor temperature, lack of refrigerant, etc. It works as supplementary of compressor motor overheat.
(4)High&low pressure protection
High pressure normally caused by poor ventilation, dusty condenser, refrigerant circuit blocking, etc.
Low temperature caused by lack of refrigerant, system blocking and so on.
(5)Returning water overheat protection
Chiller supply cold water to cool the production process, normally the returning water temperature will be 3ºC to 8ºC higher than supplied water. If the chiller is not creating cooling energy, or the chiller capacity is not enough for the application, the temperature in the circuit will get higher and higher. This will cause damage for the production even the equipment.
While a chiller got an alarm function for returning water temperature, we can learn the situation promptly and make reaction.
(6)Low water flow/level protection
For a chiller with no open-circuit water tank, there will be a water flow switch to make sure the water circuit is working, preventing both production process and chiller unit from harmed by circuit blocking or water leaking.
(7)Phase protection
If an industrial chiller was falsely wired, motors will revert, which is a serious problem for all the motors. Phase protection will remind you to connect the power in a right way.
(8)Anti-freezing protection
This function prevents the water in the circuit from freezing, so to make sure the cooling circuit working in a healthy condition. 

5. Eurostars air cooled glycol chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit(R404A,-15ºC)
Model      ESSA-03ISXTY05ISXTY08ISXTY10ISXTY12ISXTY15ISXTY
Rated Cooling CapacityKW3.02 5.18 7.52 10.55 12.20 14.35 
USRT0.86 1.47 2.14 3.00 3.47 4.08 
×1000 kcal/h2.60 4.45 6.47 9.07 10.49 12.34 
Air Cooled Chiller Unit(R404A,-15ºC)
Model      ESSA-20IDXTY25IDXTY30IDXTY40IQXTY50IQXTY60IQXTY
Rated Cooling CapacityKW21.10 24.428.742.248.857.4
USRT6.00 6.94 8.16 12.00 13.88 16.33 
×1000 kcal/h18.15 20.98 24.68 36.29 41.97 49.36 

(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. -10ºC/-15ºC
(3)Chilled glycol-waterl iquid range: -15~-5ºC; Ambient Temperature: 5ºC~43ºC.

6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards 
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle
 
7.Glycol Chiller vs. Water Chiller
(1)What Type of Coolants Are Used in Chillers?
The type of coolant utilized in a chiller is based on process needs and cost considerations. The most popular coolants used are either water or a mixture of water and another substance with suitable heat conduction properties - like glycol compounds.
Water: The use of water as chiller fluid is an economical one as in most cases the water can be easily sourced with minimal costs. Alternatively, purified (deionized water, reverse osmosis) water can be used in a water-based chiller to achieve a higher cooling efficiency.
Glycol: Glycol based coolants are either composed of ethylene glycol or propylene glycol. While these two variants have similar physical properties, they should never be mixed. The major advantages which glycol coolants confer are an improved resistance to corrosion as well as antifreeze properties.

(2)How Does a Glycol Chiller System Work?
A glycol chiller plant is composed of a refrigeration component and tubing containing a glycol-water mixture as coolant. Chilled fluid from the refrigeration unit is channeled through the piping associated with a thermal exchanger surrounding a heated process. After absorbing heat from the associated process, the warmed coolant is returned to the refrigeration unit for cooling after which the process is repeated.

Percentage Glycol in Chilled Water Systems
For many chiller types, ethylene glycol is mixed with water at a ratio of 60/40. This higher percentage of glycol boosts the mixture's antifreeze properties significantly. This is useful in cases where rapid cooling is required. In these situations, a process can be cooled to very low temperatures without freezing the coolant within its piping.

(3)How Does a Water Chiller System Work?
A conventional water chiller works on the principles of heat transmission between various mediums both fluid and solid. These cooling systems work either by heat absorption or vapor compression. The basic components of a water chiller system include a refrigeration unit and a piping system that circulated chilled coolant. 

8. Our OEM and ODM service:
EUROSTARS was established in 2006, has a professional technical team to research and develope HVAC products. We offer OEM/ODM service to our clients.
Now EUROSTARS collaborate with our clients in the following ways:
(1)Produce EUROSTARS standard products under clients' brand.
(2)Modify the products to satisfy clients' personalized requirements.
(3)If clients have their own idea and design of the products, EUROSTARS can actualize it and modify it make it easy for mass production.
(4)Based on strong capability of research and development, EUROSTARS can work together with clients to design and produce a totally new products.

9. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle


10. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

Chiller production at our previous location as below
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

11. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.

Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle

12. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle
Low Temperature Glycol Chiller Air Cooled Chiller for Reaction Kettle