China 24c Fiber Optical Cable with Figure-8 Self-Supporting Gyxtc8s Type-G, Find details about China Fiber Optic Cable Manufacturers, Self-Supporting Fiber Cable from 24c Fiber Optical Cable with Figure-8 Self-Supporting Gyxtc8s Type-G
24C Fiber Optical Cable with Figure-8 Self-Supporting GYXTC8S Type
Application:
☆.Adopted to outdoor distribution.
☆.Suitable for aerial duct and buried method.
☆.Long distance and local area network communication.
Characteristics:
☆.Stainless steel or gaivanized steel self-supporting.
☆.Excellet mechanical and environmental performance.
☆.Fiber count: 2-24 cores.
Fiber Allocation Scheme
Fiber number | Tube number | Fiber per tube | Fiber type |
2 | 1 | 2 F/Tube | SM G652D MM 50/125 MM 62.5/125 |
4 | 1 | 4 F/Tube | |
6 | 1 | 6 F/Tube | |
8 | 1 | 8 F/Tube | |
12 | 1 | 12 F/Tube | |
24 | 1 | 24 F/ Tube |
Cable Construction Details
Items | Description | |
Number of fiber | 2 cores to 24cores | |
Connector strength member | Material | Galvanized steel wire |
diameter | 1.2 mm | |
Loose tube | material | PBT |
diameter | Ф2.0-2.8 | |
Cable filling | material | Cable filling compound |
Outer sheath | material | HDPE |
diameter | 1.7±0.2mm |
Cable Mechanical Characteristic
Items | Cable diameter | Weight | |
2 cores to 24 cores | 3.2*7.2 mm | 70 kg/km | |
Installation Temperature range | -15--+60 | ||
Operation and transport temperature | -40-+70 | ||
Rec.daily max working tension | 1500 N | ||
Max. Allowable working tension | 600 N | ||
Min Bending Radius(mm) | operation | 10D mm | |
installation | 20D mm | ||
Extra load | 0.5%-0.7% | ||
Ice | 5mm | ||
Wind speed | 35m/s |
Fiber Characteristic
Fiber style | Unit | SM G652D | MM 50/125 | MM 62.5/125 | ||
condition | nm | 1310/1550 | 850/1300 | 850/1300 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.0/1.0 | ≤3.0/1.0 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≥-3.4 ≤3.4 | ..... | ..... | |
1550nm | Ps/(nm*km) | ≤18 | ..... | ..... | ||
1625nm | Ps/(nm*km) | ≤22 | ||||
Bandwidth | 850nm | MHZ. KM | ..... | >=400 | >=160 | |
1300nm | MHZ. KM | ..... | >=800 | >=500 | ||
Zero dispersion wavelength | nm | >=1302,≤1322 | ..... | ..... | ||
Zero dispersion slope | Ps(nm2*km) | ≤0.091 | ..... | ..... | ||
PMD Maximum Individual Fiber | Ps√km | ≤0.2 | ..... | ..... | ||
PMD Design Link Value | Ps√km | ≤0.08 | ..... | ..... | ||
Fibre cutoff wavelength λc | nm | >=1180,≤1330 | ..... | ..... | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ..... | ..... | ||
MFD | 1310nm | um | 9.2±0.4 | ..... | ..... | |
1550nm | um | 10.4±0.8 | ..... | ..... | ||
Numerical Aperture(NA) | ...... | 0.200±0.015 | 0.275±0.015 | |||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.10 | ≤0.10 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.10 | ≤0.10 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.08 | ≤0.10 | ||
Attenuation uniformity | dB/km | ≤0.01 | ....... | ....... | ||
Core diameter | um | ...... | 50±1.0 | 62.5±2.5 | ||
Cladding diameter | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤1.5 | ≤1.5 | ||
Curl(radius) | um | ≤4 | ..... | ..... |