Portable SF6 Dew Point Analysis Instrument With Temperature Compensation Function

China Portable SF6 Dew Point Analysis Instrument With Temperature Compensation Function, Find details about China Dew Point Tester, Dew Point Detector from Portable SF6 Dew Point Analysis Instrument With Temperature Compensation Function

Model NO.
GDWS-2
Delivery time
20 days
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
Model NO.
GDWS-2
Delivery time
20 days
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
Portable SF6 Dew Point Analysis Instrument With Temperature Compensation Function

Product Description

GDWS-II SF6 Gas Dew Point Tester is ideal device for controlling dry point in the low dew point and industrial environment. It has chemical purge options and can accurately measure in high concentrations of chemicals and cleaner environment..To ensure accurate measurement between each check interval. This function can be proceeded on the on-line and also perform regularly according to the preset time interval.

Application: Industrial gas humidity detection, such as Air, CO2, N2, H2, O2, SF6, He, Ar and some inert gases.

 

Features

  • Color LCD display.
  • Zero point calibration, with curve correction.
  • Fast measurement speed.
  • Easy operation, portable to carry.
  • Good repeat-ability and fast response speed.
  • Temperature compensation function.
  • AC/DC power supply, with over-charge and over-discharge protection.

 

Specifications
 

Power Supply220VAC±10%, 50Hz, AC/DC use, over-charge protection, continuous working is no lower than 5 hours.
Measuring RangeDew point -80~+20ºC(ppmv)
Dew point accuracy±2ºC(dew point temperature is lower than 0ºC, sensor output as the frost point).
Response time63%[90%], +20→-20ºC Td 5s[45s], -20→-60ºC Td 10s[240s]
ResolutionDew point 0.1ºC or 0.1ppm
Repeat-ability±0.5ºC
Gas flow0.8~0.9L/min(SF6 Gas etc.);
0.2~0.6L/min(H2 Gas etc.),
Electronic mass flow meter, sample gas flow rate without any effect.
Pressure measurement0~1.0MPa
Probe protection Sintered stainless steel filter
Working voltage220VAC±10%  50Hz, AC & DC, the overcharge protection, not less than 5 hours of continuous work.
Storage temperature level-40~+70ºC
Output interfaceUSB
Operate temperature-30~+60ºC
Pressure0-20bar
With management software, including report printing, electronic quality flow meter.
Dimension130*283*308mm
WeightAbout 4.3kg