China Air Piezoresistive Piezoresistive Customized Compact Temperature Compensated Pressure Sensor, Find details about China Pressure Sensor, Temperature Compensated Pressure Sensor from Air Piezoresistive Piezoresistive Customized Compact Temperature Compensated Pressure Sensor
Item* | Min. | Typ. | Max. | Units |
Linearity | ±0.15 | ±0.25 | %FS,BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Zero output | ±2 | mVDC | ||
FS output** | 70 | mVDC | ||
Zero thermal error | ±0.75 | ±1.0 | %FS, @25ºC | |
FS thermal error | ±0.75 | ±1.0 | %FS, @25ºC | |
Compensated temp. range | 0~50 | ºC | ||
Working temp. range | -40~125 | ºC | ||
Storage temp. range | -40~125 | ºC | ||
Stability | ±0.2 | ±0.3 | %FS/year | |
*testing at basic condition,G: Gauge; A: Absolute; S: Sealed gauge ** 0AG, FS output ≥60mV 0BG, FS output ≥45mV 02A, 03A, 02GY, 03GY, FS output ≥50mV 07A, 08A, 07GY, 08GY, FS output ≥60mV |
MPM280(TS/TH/Ti)* | Piezoresistive OEM Pressure Sensor | |||||||||||||||||
Range code | Pressure range | Ref. | Range code | Pressure range | Ref. | |||||||||||||
0B | 0~20kPa | G | 10 | 0~1MPa | G.A | |||||||||||||
0A | 0~35kPa | G | 12 | 0~2MPa | G.A | |||||||||||||
02 | 0~70kPa | G.A | 13 | 0~3.5MPa | G.S.A | |||||||||||||
03 | 0~100kPa | G.A | 14 | 0~7MPa | S | |||||||||||||
07 | 0~200kPa | G.A | 15 | 0~10MPa | S | |||||||||||||
08 | 0~350kPa | G.A | 17 | 0~20MPa | S | |||||||||||||
09 | 0~700kPa | G.A | 18 | 0~35MPa | S | |||||||||||||
Code | Pressure type | |||||||||||||||||
G | Gauge | |||||||||||||||||
A | Absolute | |||||||||||||||||
S | Sealed gauge | |||||||||||||||||
Code | Pressure connection | Installation | ||||||||||||||||
0 or null | O-ring | |||||||||||||||||
1 | Assembled M20x1.5 male, waterline seal | Top: M24x1 male (P≤2MPa) | ||||||||||||||||
2 | Assembled M20x1.5 male, waterline seal | Top: M27x2 male | ||||||||||||||||
3 | Welded M20x1.5 male, waterline seal | Top: M24x1 male (P≤2MPa) | ||||||||||||||||
4 | Welded M20x1.5 male, waterline seal | Top: M27x2 male | ||||||||||||||||
PC1 | Flush diaphragm M20x1.5 male, | Top: M24x1 female | ||||||||||||||||
PC3 | Flush diaphragm G1/2 male, | Top: M24x1 female | ||||||||||||||||
Code | Compensation | |||||||||||||||||
L | Laser trimming | |||||||||||||||||
M | Outer compensated resistor (providing resistor value) | |||||||||||||||||
Code | Electric connection | |||||||||||||||||
1 | φ0.5mm Kovar pin | |||||||||||||||||
3 | 4-color flexible wire, default length:100mm | |||||||||||||||||
Code | Special measurement | |||||||||||||||||
Y | Gauge sensor to measure vacuum (0~ -100kPa) | |||||||||||||||||
MPM280 09 G 0 L 1 Y The whole spec | ||||||||||||||||||