Lh Ovulation Reagent Strip / Cassette / Midstream Test

China Lh Ovulation Reagent Strip / Cassette / Midstream Test, Find details about China Lh Test Strip, Lh Ovulation from Lh Ovulation Reagent Strip / Cassette / Midstream Test

Model NO.
LH01
Name
Lh Test
Function
for Female to Test
Package
OEM
Format
Strip, Cassette, Midstream
Specimen
Urine/Serum
Sensitivity
10-25miu/Ml
Size
2.5mm, 3.0mm, 4.0mm, 5.5mm, 6.0mm
Cetificate
ISO13485, Fsc
Transport Package
1PCS/Foil Pouch
Specification
2.5mm, 3.0mm
Origin
Rugao, Nantong, Jiangsu, China
HS Code
3822001000
Model NO.
LH01
Name
Lh Test
Function
for Female to Test
Package
OEM
Format
Strip, Cassette, Midstream
Specimen
Urine/Serum
Sensitivity
10-25miu/Ml
Size
2.5mm, 3.0mm, 4.0mm, 5.5mm, 6.0mm
Cetificate
ISO13485, Fsc
Transport Package
1PCS/Foil Pouch
Specification
2.5mm, 3.0mm
Origin
Rugao, Nantong, Jiangsu, China
HS Code
3822001000
One Step LH Ovulation rapid test strip

The One Step LH Urine Ovulation Test is fast and easy to use. It is a qualitative test that can predict when there is a LH (luteinizing hormone) surge, and in turn, when you are likely to ovulate. 
Lh Ovulation Reagent Strip / Cassette / Midstream TestLh Ovulation Reagent Strip / Cassette / Midstream Test


Related information
Accuracy: >99%
Origin: China
Using: self-test

 
Diagnos LH Ovulation Test
Product CodeDNSLH02
FormatA. Strip
B.cassette
C.midstream
Specimenurine
Sensitivity ng/ml10-25 mIU/ml
Size(mm)A.strip:2.5, 3.0, 3.5, 4.0 
B.cassette: 3.0, 4.0 
C.midstream:4.5,5.5,6.0
Packing, OEM service are also acceptedA.strip:1 test in a single pouch, 5000pcs in a carton cassette
B. cassette:1 test in a single pouch, 2000pcs in a carton
C.midstream: 1 test in a single pouch, 1000pcs in a carton
AccuracyOver 99.5%
CertificateCE,ISO9001,ISO13485
Sample Lead timeWithin 7 days if we have stocks
Loading PortNantong / Shanghai/ customers' needs

TEST PROCENURE
1. Allow the sealed LH test pouch, urine sample, and control solution to reach room temperature (18-30°C).
 
2. Remove the LH test strip from the sealed pouch.
 
3. Immerse the strip into the urine with the arrow end pointing towards the urine. Do not immerse past the MAX
 (marker line). Take the strip out after 5 seconds and lay the strip flat on a clean, dry, non-absorbent surface (such as the mouth of the urine container).
 
4. Wait for colored bands to appear. Depending on the concentration of LH in the test specimen, positive results
 may be observed in as little as 40 seconds. However, to confirm negative results, the complete reaction time of 
10 minutes is required. Do not read results after more than 30 minutes.
Lh Ovulation Reagent Strip / Cassette / Midstream TestLh Ovulation Reagent Strip / Cassette / Midstream Test


FAQ

Q1.What's the method you use to do the test?

A: Colloidal Gold Method.

Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.  

Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.

Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.

Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.

Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts: 
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.