Competitive Automatic Chemical Flat Glass Tempering Furnace for 0.5-3mm Ultra-Thin Electronic Glass China Supplier, Find details about China Chemical Glass Tempering Furnace, Tempering Furnace from Competitive Automatic Chemical Flat Glass Tempering Furnace for 0.5-3mm Ultra-Thin Electronic Glass China Supplier
Device Operating Voltage | 3-phase 5-wire, AC380V |
Heater Power | 256KW |
Heating Blower Power | 4 set*3.0KW |
Cooling Blower Power | 2 set*1.5KW |
Load Motor Power Shift | 2 set*4.0KW |
Total Power | 800-1200KW |
Weight(kg) | About 18 T |
Designation | Detail Description |
Capacity | 6-8hours/furnace |
Equipment Loading | 24 hours system( Two classes or three shifts) |
Overall Dimension | 13850mm(L)x8700mm(W)x7400mm(H) |
The Dimension of Inner Tank | 2500mm(L)x3500mm(W)x2800mm(H) |
The Dimension of Hanging Basket | 2300mm(L)x3170mm(W)x2520mm(H) |
Security | Electrical performance :E-level, and have a good grounding ,resistance over 500 MΩ. |
Security protection: it must be to installed with security doors or security cover on the place which is easy to cause harm to human body. | |
The emergency stop switch: setting the emergency stop switch on the surface of the operation control box ,it must set the emergency stop switch prominently beside the work positions operation switch | |
The emergency stop switch: setting the emergency stop switch on the surface of the operation control box ,it must set the emergency stop switch prominently beside the work positions operation switch | |
Control System | Mitsubishi PLC series is responsible for all procedures, actions, temperature control, event logging. |
PVA parameter interface touchscreen charge, temperature, status display, alarm display lamp. | |
Electrical box using T = 2mm cold rolled paint treatment, with air conditioning and ventilation. | |
System Functions | Complete automation of the whole process, to warm to directly perform the next step, unattended. |
Furnace temperature storage, and logging capabilities historical events, alarm queries, event trace function. | |
Parameter setting, multi-stage preheating and cooling parameters set multi-level cryptographic devices to prevent parameter tampering | |
The parameters of detection and alarm equipment overheating protection function. | |
Double stroke limit switches to protect the furnace safe and reliable mechanical movement. |