Model | M-HA9500 |
Display | Digital screen |
Ventilation Mode | IPPV,SIPPV,MANUAL,STBY |
Gas Source | O2: 0.45Mpa±0.05Mpa |
N2O: 0.45Mpa±0.05Mpa | |
Power Source | AC:100V-240V 50/60Hz |
Features | *Classic electropneumatic ventilator,widely apply for adults and children; *High-precision four-tube flowmeters; nitrous oxide-oxygen anesthesia to ensure that the oxygen concentration is not less than 25%; *Sophisticated monitoring of anesthesia respiratory parameters and alarm functions; *Humanized interface, clearly shows the working state of the anesthesia machine, with a more comfortable operation feeling and visual sense; *Advanced gas-electric isolation system eliminates the oxygen enrichment; *With standard large-capacity maintenance-free battery, the machine can work continuously for not less than 8 hours. *Modular design reduces potential leaks, misconnections and detachments of tube; *Classic rising bellows can monitor the patient's breathing and detect leakproofness of circuit; *Large- capacity CO2 absorption system; *AGSS (optional) can effectively control pollution of anesthetic waste gas, clean surgical room, care for health of medical staff. |
Precise Control | *The minimum tidal volume can be low to 10ml; *Adopt international top control valves, sensor components; *Sophisticated information control system. |
Anesthetic Evaporator | *Two Vaporizer station ; *Temperature compensation function,; *Flow compensation function ; *Pressure compensation function; *Precise concentration output ensures safe operation of low flow and micro flow. |
Breathing Circuit | *Modular design, original anti-water technology; *Large-capacity CO2 absorption tank (1.6L) ; *Easy to take part . |
Alarm Function | *Tidal volume limit alarm, minute ventilation volume limit alarm; *Gas shortage alarm, battery shortage alarm; *Power failure alarm; *Continuous airway high pressure alarm. |
Model | M-HA9600 |
Ddiplay | 5.6"LCD Screen |
Ventilation Mode | IPPV,SIPPV,MANUAL,STBY,SIGH,SPONT |
Gas Source | O2: 0.45Mpa±0.05Mpa |
N2O: 0.45Mpa±0.05Mpa | |
Power Source | AC:100V-240V 50/60Hz |
Features | *Classic electropneumatic ventilator,widely apply for adults and children; *High-precision four-tube flowmeters; nitrous oxide-oxygen anesthesia to ensure that the oxygen concentration is not less than 25%; *Sophisticated monitoring of anesthesia respiratory parameters and alarm functions; *Humanized interface, clearly shows the working state of the anesthesia machine, with a more comfortable operation feeling and visual sense; *Advanced gas-electric isolation system eliminates the oxygen enrichment; *With standard large-capacity maintenance-free battery, the machine can work continuously for not less than 8 hours. *Modular design reduces potential leaks, misconnections and detachments of tube; *Classic rising bellows can monitor the patient's breathing and detect leakproofness of circuit; *Large- capacity CO2 absorption system; *AGSS (optional) can effectively control pollution of anesthetic waste gas, clean surgical room, care for health of medical staff. |
Precise Control | *The minimum tidal volume can be low to 10ml; *Adopt international top control valves, sensor components; *Sophisticated information control system. |
Anesthetic Evaporator | *Two Vaporizer station ; *Temperature compensation function,; *Flow compensation function ; *Pressure compensation function; *Precise concentration output ensures safe operation of low flow and micro flow. |
Breathing Circuit | *Modular design, original anti-water technology; *Large-capacity CO2 absorption tank (1.6L) ; *Easy to take part . |
Alarm Function | *Tidal volume limit alarm, minute ventilation volume limit alarm; *Gas shortage alarm, battery shortage alarm; *Power failure alarm; *Continuous airway high pressure alarm; *Oxygen limit alarm. |
Model | M-HA9800 |
Ddiplay | 10.4"LCD bulid-in screen |
Ventilation Mode | IPPV,SIPPV,PCV,PEEP,MANUAL,STBY,SIGH |
Gas Source | O2: 0.45Mpa±0.05Mpa |
Air:0.45Mpa±0.05Mpa | |
N2O: 0.45Mpa±0.05Mpa | |
Power Source | AC:100V-240V 50/60Hz |
Features | *Classic electropneumatic ventilator,widely apply for adults and children; *High-precision four-tube flowmeters; nitrous oxide-oxygen anesthesia to ensure that the oxygen concentration is not less than 25%; *Sophisticated monitoring of anesthesia respiratory parameters and alarm functions; *Humanized interface, clearly shows the working state of the anesthesia machine, with a more comfortable operation feeling and visual sense; *Advanced gas-electric isolation system eliminates the oxygen enrichment; *With standard large-capacity maintenance-free battery, the machine can work continuously for not less than 8 hours. *Modular design reduces potential leaks, misconnections and detachments of tube; *Classic rising bellows can monitor the patient's breathing and detect leakproofness of circuit; *Large- capacity CO2 absorption system; *AGSS (optional) can effectively control pollution of anesthetic waste gas, clean surgical room, care for health of medical staff. |
Precise Control | *The minimum tidal volume can be low to 10ml; *Adopt international top control valves, sensor components; *Sophisticated information control system. |
Anesthetic Evaporator | *Two Vaporizer station ; *Temperature compensation function,; *Flow compensation function ; *Pressure compensation function; *Precise concentration output ensures safe operation of low flow and micro flow. |
Breathing Circuit | *Modular design, original anti-water technology; *Large-capacity CO2 absorption tank (1.6L) ; *Easy to take part . |
Alarm Function | *Tidal volume limit alarm, minute ventilation volume limit alarm; *Gas shortage alarm, battery shortage alarm; *Power failure alarm; *Continuous airway high pressure alarm; *Oxygen limit alarm. |