China Solar Product 12V 220V 12kw DC/AC Three Phase Frequency Pure Sine Wave UPS Home Power off Grid Grid Tie Charger Solar Pump Power Hybrid Solar Inverter, Find details about China Power Inverters, Solar Inverter from Solar Product 12V 220V 12kw DC/AC Three Phase Frequency Pure Sine Wave UPS Home Power off Grid Grid Tie Charger Solar Pump Power Hybrid Solar Inverter
Model | AU-3P8K1G-LE | AU-3P10K1G-LE | AU-3P12K1G-LE | |
Name | Solar Product 12v 220v 12kw dc/ac three phase Frequency pure sine wave ups home power off grid grid tie charger Solar Pump power hybrid solar inverter | |||
Battery Input Data | ||||
Battery Type | Lead-acid or Lithium-ion | |||
Battery Voltage Range (V) | 40V~60V | |||
Max.Charging Current (A) | 190A | 210A | 240A | |
Max.Discharging Current(A) | 190A | 210A | 240A | |
Charging Curve | 3 Stages/Equalization | |||
External Temperature Sensor | Optional | |||
Charging Strategy for Li-lon Battery | Self-adaption to BMS | |||
PV String Input Data | ||||
Max.DC Input Power (W) | 10400W | 13000W | 15600W | |
PV Input Voltage (V) | 450V(140V~1000V) | |||
MPPT Range (V) | 140~800V | |||
Start-up Voltage (V) | 160V | |||
PV Input Current (A) | 12.5A+12.5A | 25A+12.5A | 25A+12.5A | |
No.of MPPT Trackers | 2 | |||
No.of String Per MPPT Tracker | 1+1 | 2+1 | 2+1 | |
AC Output Data | ||||
Rated AC Output and UPS Power (W) | 8000W | 10000W | 12000W | |
Max AC OutputPower (W) | 8800W | 11000W | 13200W | |
Peak Power(off grid) | 2 times of rated power, 10 S | |||
AC Output Rated Current (A) | 11.6A | 14.5A | 17.4A | |
Max.AC Current(A) | 12.8A | 16A | 19.1A | |
Max Continuous AC Passthrough(A) | 60A | 60A | 60A | |
Output Frequency and Voltage | 50/60HZ; 230/400Vac(three phase) | |||
Grid Type | Three Phase | |||
Current Harmonic Distortion | THD<3%(Linear load<1.5%) | |||
Efficiency | ||||
Max.Efficiency | 97.60% | |||
Euro Efficiency | 97.00% | |||
MPPT Efficiency | 99.90% | |||
Protection | ||||
PV Input Lighting Protection | Integrated | |||
Anti-islanding Protection | Integrated | |||
PV String Input Reverse Polarity Protection | Integrated | |||
Insulation Resistor Detection | Integrated | |||
Residual Current Montioring Unit | Integrated | |||
Output Over Current Protection | Integrated | |||
Output Shorted Protection | Integrated | |||
Output Over Voltage Protection | Integrated | |||
Surge protection | DC type II/AC type II | |||
Certifications and Standards | ||||
Grid Regulation | UL1741, IEEE 1547, VDE 0126, AS4777, NRS 2017, G98, G99, IEC61683,IEC62116, IEC61727, IEC62109-1, IEC62109-2 | |||
Safety Regulation | IEC62109-1, IEC62109-2 | |||
EMC | EN61000-6-1, EN61000-6-3,FCC 15 class B | |||
General Data | ||||
Operating Tenperature Range (ºC) | -25~60ºC,>45ºC Derating | |||
Cooling | Fan | |||
Noise (dB) | <30 dB | |||
Communication with BMS | RS485;CAN | |||
Weight (kg) | 45 | |||
Size(Length*width*Height mm) | 656W×420H×256D | |||
Protection Degree | IP65 | |||
Installation Style | Wall-mounted | |||
Warranty | 5 years |