33kv XLPE Insulated Unarmoured Electric Cable, Power Cable

China 33kv XLPE Insulated Unarmoured Electric Cable, Power Cable, Find details about China Cable, Power Cable from 33kv XLPE Insulated Unarmoured Electric Cable, Power Cable

Model NO.
YJV YJV32 JYV22 YJLV
Wire Core Material
Bare Copper Wire
Certification
ISO, CE, SABS
Brand
Henan Jiapu
Voltage Rating
0.6/1 Kv 3.6/6 Kv
No.of Cores
1-5 Cores
Applicable Standard
IEC60502 IEC60331 DIN BS
Max Working Temp
90 Degrees
Max Shott Circuit Temp
250 Degrees
Trademark
Jiapu
Transport Package
wooden drum or wooden&steel drum
Specification
IEC, ASTM, DIN, BS, GB, Any standard
Origin
Henan China
HS Code
4101962331
Model NO.
YJV YJV32 JYV22 YJLV
Wire Core Material
Bare Copper Wire
Certification
ISO, CE, SABS
Brand
Henan Jiapu
Voltage Rating
0.6/1 Kv 3.6/6 Kv
No.of Cores
1-5 Cores
Applicable Standard
IEC60502 IEC60331 DIN BS
Max Working Temp
90 Degrees
Max Shott Circuit Temp
250 Degrees
Trademark
Jiapu
Transport Package
wooden drum or wooden&steel drum
Specification
IEC, ASTM, DIN, BS, GB, Any standard
Origin
Henan China
HS Code
4101962331
33kv XLPE Insulated Unarmoured electric cable, power cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.


Specification:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.12

1.5

17.6

0.34

0.49

1.2000

0.7270

35

7.0

2.5

0.12

1.5

18.5

0.39

0.60

0.8680

0.5240

50

8.3

2.5

0.12

1.6

20.0

0.46

0.74

0.6410

0.3870

70

9.7

2.5

0.12

1.6

21.5

0.55

0.96

0.4430

0.2680

95

11.3

2.5

0.12

1.7

23.3

0.66

1.23

0.3200

0.1930

120

13

2.5

0.12

1.7

24.8

0.77

1.48

0.2530

0.1530

150

14.6

2.5

0.12

1.8

26.4

0.87

1.77

0.2060

0.1240

185

15.9

2.5

0.12

1.8

28.1

1.01

2.13

0.1640

0.0991

240

18.3

2.6

0.12

1.9

30.9

1.23

2.71

0.1250

0.0754

300

20.4

2.8

0.12

2.0

33.6

1.48

3.32

0.1000

0.0601

400

23.2

3.0

0.12

2.1

37.0

1.81

4.16

0.0778

0.0470

500

26.4

3.2

0.12

2.2

41.1

2.24

5.27

0.0605

0.0366

630

30.1

3.2

0.12

2.3

45.0

2.73

6.62

0.0469

0.0283


2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.12

1.5

19.4

0.40

0.55

1.2000

0.7270

35

6.9

3.4

0.12

1.6

20.5

0.45

0.66

0.8680

0.5240

50

8.2

3.4

0.12

1.6

21.8

0.52

0.80

0.6410

0.3870

70

9.7

3.4

0.12

1.7

23.5

0.62

1.03

0.4430

0.2680

95

11.3

3.4

0.12

1.7

25.1

0.73

1.30

0.3200

0.1930

120

12.8

3.4

0.12

1.8

26.8

0.85

1.56

0.2530

0.1530

150

14.2

3.4

0.12

1.8

28.2

0.95

1.85

0.2060

0.1240

185

15.9

3.4

0.12

1.9

30.1

1.10

2.22

0.1640

0.0991

240

18.3

3.4

0.12

2.0

32.7

1.33

2.80

0.1250

0.0754

300

20.4

3.4

0.12

2.0

34.8

1.54

3.39

0.1000

0.0601

400

23.2

3.4

0.12

2.2

38.0

1.87

4.22

0.0778

0.0470

500

26.4

3.4

0.12

2.2

41.5

2.26

5.29

0.0605

0.0366

630

30.1

3.4

0.12

2.4

45.6

2.78

6.67

0.0469

0.0283


3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.12

1.6

21.8

0.48

0.63

1.2000

0.7270

35

6.9

4.5

0.12

1.7

22.9

0.54

0.75

0.8680

0.5240

50

8.2

4.5

0.12

1.7

24.2

0.61

0.89

0.6410

0.3870

70

9.7

4.5

0.12

1.8

25.9

0.72

1.13

0.4430

0.2680

95

11.3

4.5

0.12

1.8

27.5

0.84

1.40

0.3200

0.1930

120

12.8

4.5

0.12

1.9

29.2

0.96

1.67

0.2530

0.1530

150

14.2

4.5

0.12

1.9

30.6

1.06

1.96

0.2060

0.1240

185

15.9

4.5

0.12

2.0

32.5

1.22

2.34

0.1640

0.0991

240

18.3

4.5

0.12

2.1

35.1

1.46

2.93

0.1250

0.0754

300

20.4

4.5

0.12

2.1

37.2

1.68

3.52

0.1000

0.0601

400

23.2

4.5

0.12

2.2

40.2

2.00

4.35

0.0778

0.0470

500

26.4

4.5

0.12

2.3

43.9

2.43

5.45

0.0605

0.0366

630

30.1

4.5

0.12

2.4

47.8

2.93

6.83

0.0469

0.0283


4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

6.9

5.5

0.12

1.7

24.9

0.62

0.83

0.8680

0.5240

50

8.2

5.5

0.12

1.8

26.4

0.70

0.98

0.6410

0.3870

70

9.7

5.5

0.12

1.8

27.9

0.80

1.21

0.4430

0.2680

95

11.3

5.5

0.12

1.9

29.7

0.94

1.50

0.3200

0.1930

120

12.8

5.5

0.12

1.9

31.2

1.05

1.77

0.2530

0.1530

150

14.2

5.5

0.12

2.0

32.8

1.17

2.07

0.2060

0.1240

185

15.9

5.5

0.12

2.0

34.5

1.33

2.45

0.1640

0.0991

240

18.3

5.5

0.12

2.1

37.1

1.57

3.04

0.1250

0.0754

300

20.4

5.5

0.12

2.2

39.4

1.81

3.66

0.1000

0.0601

400

23.2

5.5

0.12

2.3

42.4

2.14

4.49

0.0778

0.0470

500

26.4

5.5

0.12

2.4

46.1

2.58

5.61

0.0605

0.0366

630

30.1

5.5

0.12

2.4

49.8

3.10

6.99

0.0469

0.0283


5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.12

2.0

31.8

0.95

1.23

0.6410

0.3870

70

9.7

8.0

0.12

2.0

33.3

1.07

1.47

0.4430

0.2680

95

11.3

8.0

0.12

2.1

35.1

1.21

1.78

0.3200

0.1930

120

12.8

8.0

0.12

2.1

36.6

1.34

2.05

0.2530

0.1530

150

14.2

8.0

0.12

2.2

38.2

1.47

2.37

0.2060

0.1240

185

15.9

8.0

0.12

2.2

39.9

1.64

2.76

0.1640

0.0991

240

18.3

8.0

0.12

2.3

42.5

1.90

3.37

0.1250

0.0754

300

20.4

8.0

0.12

2.4

44.8

2.16

4.01

0.1000

0.0601

400

23.2

8.0

0.12

2.4

47.6

2.52

4.87

0.0778

0.0470

500

26.4

8.0

0.12

2.5

51.3

2.98

6.01

0.0605

0.0366

630

30.1

8.0

0.12

2.6

55.2

3.54

7.43

0.0469

0.0283


6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.1

2.0

34.6

1.13

1.58

1.2000

0.7270

35

6.9

2.5

0.1

2.1

36.8

1.29

1.92

0.8680

0.5240

50

8.2

2.5

0.1

2.2

39.8

1.51

2.36

0.6410

0.3870

70

9.7

2.5

0.1

2.3

43.2

1.81

3.04

0.4430

0.2680

95

11.3

2.5

0.1

2.4

46.9

2.17

3.87

0.3200

0.1930

120

12.8

2.5

0.1

2.4

50.1

2.53

4.69

0.2530

0.1530

150

14.2

2.5

0.1

2.5

53.3

2.90

5.60

0.2060

0.1240

185

15.9

2.5

0.1

2.6

57.2

3.40

6.77

0.1640

0.0991

240

18.3

2.6

0.1

2.8

63.2

4.12

8.55

0.1250

0.0754

300

20.4

2.8

0.1

3.0

69.0

4.89

10.46

0.1000

0.0601

400

23.2

3.0

0.1

3.4

76.7

6.10

13.18

0.0778

0.0470

500

26.4

3.2

0.1

3.6

85.7

8.10

16.55

0.0605

0.0366


7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.1

2.1

38.7

1.30

1.75

1.2000

0.7270

35

6.9

3.4

0.1

2.2

40.9

1.47

2.22

0.8680

0.5240

50

8.2

3.4

0.1

2.3

43.9

1.70

2.50

0.6410

0.3870

70

9.7

3.4

0.1

2.4

47.3

2.02

3.25

0.4430

0.2680

95

11.3

3.4

0.1

2.5

51.0

2.42

4.12

0.3200

0.1930

120

12.8

3.4

0.1

2.6

54.4

2.79

4.95

0.2530

0.1530

150

14.2

3.4

0.1

2.7

57.6

3.17

5.87

0.2060

0.1240

185

15.9

3.4

0.1

2.8

61.5

3.69

7.06

0.1640

0.0991

240

18.3

3.4

0.1

2.9

66.9

4.38

8.82

0.1250

0.0754

300

20.4

3.4

0.1

3.1

71.8

5.11

10.68

0.1000

0.0601

400

23.2

3.4

0.1

3.3

78.3

6.24

13.32

0.0778

0.0470

500

26.4

3.4

0.1

3.5

86.4

7.63

16.50

0.0605

0.0366


8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.1

2.3

43.9

1.57

2.02

0.9270

0.7270

35

6.9

4.5

0.1

2.4

46.0

1.75

2.38

0.6680

0.5240

50

8.2

4.5

0.1

2.4

48.8

2.00

2.85

0.4936

0.3870

70

9.7

4.5

0.1

2.5

52.3

2.34

3.57

0.3420

0.2680

95

11.3

4.5

0.1

2.6

55.9

2.75

4.45

0.2464

0.1930

120

12.8

4.5

0.1

2.7

59.4

3.16

5.32

0.1955

0.1530

150

14.2

4.5

0.1

2.8

62.6

3.57

6.27

0.1587

0.1240

185

15.9

4.5

0.1

2.9

66.4

4.07

7.45

0.1271

0.0991

240

18.3

4.5

0.1

3.1

72.0

4.82

9.25

0.0976

0.0754

300

20.4

4.5

0.1

3.3

77.0

5.71

11.28

0.0778

0.0601

400

23.2

4.5

0.1

3.4

83.2

6.78

13.86

0.0615

0.0470

500

26.4

4.5

0.1

3.5

91.1

8.20

17.32

0.0487

0.0366


9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm2

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

-

 

 

 

 

 

 

 

 

35

6.9

5.5

0.1

2.4

50.3

2.00

2.63

0.8680

0.6680

50

8.2

5.5

0.1

2.5

53.3

2.26

3.11

0.6410

0.4936

70

9.7

5.5

0.1

2.6

56.8

2.62

3.85

0.4430

0.3420

95

11.3

5.5

0.1

2.8

60.6

3.07

4.77

0.3200

0.2464

120

12.8

5.5

0.1

2.9

64.1

3.49

5.65

0.2530

0.1955

150

14.2

5.5

0.1

3.0

67.3

3.91

6.61

0.2060

0.1587

185

15.9

5.5

0.1

3.1

71.2

4.44

7.81

0.1640

0.1271

240

18.3

5.5

0.1

3.3

76.8

5.21

9.64

0.1250

0.0976

300

20.4

5.5

0.1

3.3

81.3

6.10

11.66

0.1000

0.0778

400

23.2

5.5

0.1

3.5

87.7

7.20

14.28

0.0778

0.0615

500

26.4

5.5

0.1

3.8

96.0

9.15

17.80

0.0605

0.0487


10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.1

2.9

64.9

3.02

3.87

0.6410

0.4936

70

9.7

8.0

0.1

3.0

68.4

3.42

4.65

0.4430

0.3420

95

11.3

8.0

0.1

3.1

72.0

3.89

5.59

0.3200

0.2464

120

12.8

8.0

0.1

3.3

75.7

4.39

6.54

0.2530

0.1955

150

14.2

8.0

0.1

3.3

78.7

4.85

7.55

0.2060

0.1587

185

15.9

8.0

0.1

3.4

82.6

5.42

8.79

0.1640

0.1271

240

18.3

8.0

0.1

3.5

88.0

6.22

10.66

0.1250

0.0976

300

20.4

8.0

0.1

3.7

92.9

7.20

12.77

0.1000

0.0778

400

23.2

8.0

0.1

3.9

99.3

8.38

15.46

0.0778

0.0615

500

26.4

8.0

0.1

4.2

107.6

10.15

18.85

0.0605

0.0487
 


Workshop:
33kv XLPE Insulated Unarmoured Electric Cable, Power Cable


 
Shipment:
33kv XLPE Insulated Unarmoured Electric Cable, Power Cable


 
Customer:
33kv XLPE Insulated Unarmoured Electric Cable, Power Cable

 
Certification:
33kv XLPE Insulated Unarmoured Electric Cable, Power Cable

 
FAQ:

1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables. 

8. Do you supply the customers with installation service in foreign country ?
We don't have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.