J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition

China J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition, Find details about China Thermocouple Signal to RS232, Thermocouple Signal to RS485 from J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition

Model NO.
SY AD-02T
Isolation Voltage
3000V
Weight
120g
Operation Temperature
45 ~ +80centigrade
Dimension
101 Mm X 23 Mm X 116.5 Mm
Trademark
SUNYUAN
Transport Package
Carton
Specification
CE/RoHS/ISO9001: 2000/2008 Certified
Origin
Shenzhen, China
HS Code
8471800000
Model NO.
SY AD-02T
Isolation Voltage
3000V
Weight
120g
Operation Temperature
45 ~ +80centigrade
Dimension
101 Mm X 23 Mm X 116.5 Mm
Trademark
SUNYUAN
Transport Package
Carton
Specification
CE/RoHS/ISO9001: 2000/2008 Certified
Origin
Shenzhen, China
HS Code
8471800000
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition


The model selection of SY AD-02T series is just initial type of thermocouple which supports by the module. User can change the types of thermocouple by re-configurating the module through ASCII character command, then calibrate it.
SYAD08T series modules support both RS232 and RS485 communication interface. User can choose the communication interface according to the application environment, and at the same time only one interface works,otherwise it may interference with each other.
Themalcouple A-D Converter Technical Parameter:
(typical @ +25ºC,Vs is rated value)
Input: Thermocouple: J type: 0ºC~760ºC,K type: 0ºC~1000ºC,T type:-100ºC~400ºC,
       E type:0ºC~1000ºC,R type: 500ºC~1750ºC,S type:500ºC~1750ºC,B type: 500ºC~1800ºC
       (Input type can be set through software)
Accuracy: @+25ºC as shown in Table 1.
Input Imbalance: ±0.02 uV/ºC
Temperature Drift: ±1 ppm/ºC(±3 ppm/ºC, Max.)
Input Resistance: 100 M Ω
Band width: thermocouple   -3 dB 3.27 Hz
Switching rate: thermocouple     3.76 Sps
Common mode restraint (CMR): 120 dB(1kΩ Source Imbalance @ 50/60 Hz)
Normal mode restraint (NMR):  60 dB (1kΩ Source Imbalance @ 50/60 Hz)
Input terminal protection: 240Vrms, sustainable
                           ANSI/IEEE C37.90.1-1989 transient protection
 
Cold Junction Compensation Sensor
Accuracy: @+25ºC          ±0.25ºC (±0.75ºC, Max.)
Accuracy: +5ºC~+45ºC     ±0.5ºC (Non-linearity ±0.0125ºC/ºC)
Communication:  RS-485 interface or RS-232 interface;ASCII character protocol and MODBUS RTU communication protocol. Baud rage(300bps,600 bps,1200 bps,2400 bps,4800 bps,9600 bps,19200 bps,38400bps)(can be set through software).
Address (00H~FFH)can be set through software
Response time: 100 ms Max.
Operation Power Supply:+8 ~ 50 VDC wide range power,internal anti-inverse connection and over-voltage protection circuit.
Power Consumption:≤1W
Operation Temperature:- 45 ~ +85ºC         
Operation Humidity:10 ~ 90% (no dew)
Storage Temperature:- 45 ~ +85ºC               
Storage Humidity:10 ~ 95% (no dew)                                    
Isolation Withstand Voltage: 3KVDC between input and output,1 minute,stray current 1mA, Output and power are common-ground
Endure Impact Voltage: 3KVAC, 1.2/50us(peak value)
Dimension:101 mm  x  23 mm  x  116.5 mm
Weight:about 120g
item noSYAD02T
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition
J/K/T/E/R/S/B Type Thermocouple Signal Converter RS232 RS485 Converter Data Acquisition